ES S16S-J1000-R
The high density SAS-to-SAS JBOD enclosures house either SAS or SATA-II drives, combing the performance and connectivity benefits of SAS drives, and also having cost advantages with SATA drives. The J1000-R provides fault-tolerant links across separate SAS domains.
- Highlights
- Specifications
- Accessories
-
Expansion enclosure for SAS to SAS RAID systems
- SAS drives for high performance and high reliability
- SATA drives for low cost and high capacity applications
- Highest density, 16 drives in 3U rack space
- Redundant or single JBOD controllers
- Two (2) SAS 4x wide ports per controller
- Diagnostics LED panel
- Path redundancy via separate SAS domains( S16S-J1000-R)
Host-to-Drive Interface | JBOD Model | Corresponding RAID Subsystem(s) | Configuration | Form Factor | |
---|---|---|---|---|---|
Model | Max. Connection | ||||
SAS to SAS | S16S-J1000-R | 3 JBODs | Redundant Expander Controllers | 3U rack- mount | |
A24F-R2430 A24S-R2130 |
2 JBODs | ||||
S16F-R1840 | 6 JBODs | ||||
S24F-R1440 | 5 JBODs |
Host Interface
- Two (2) SAS 4x wide ports per controller.
- Proprietary enclosure service via in-band methodology
Drive Interface
- Sixteen (16) hot swappable SAS disk drives
- MUX kits with port selectors for dual-controller access to SATA drives
System Components
- Redundant or single JBOD controller configurations
- Fault-tolerant modules interfaced through a common backplane
- Redundant, hot swappable 530W power supply units
- Redundant, dual-speed cooling modules
- LED diagnostics panel
Management
- Management of multiple enclosures via RAID firmware and/or through GUI
-
Module status LED indicators:
- Six (6) LED on panel (1 service LED and 5 status LEDs)
- Two (2) per drive tray
- Three (3) per controller module (1 Ready/Failed LED and two (2) Link status LEDs)
- One (1) per power supply unit
- Two (2) per cooling module
Power Supply Module
Power Requirements | |
---|---|
Power Consumption | 530W |
Input Voltage |
100VAC @ 9A 240VAC @ 4.5A with PFC (auto-switching) |
Frequency | 47-63Hz |
Cooling Module
Specifications | |
---|---|
Speed | High or low rotation speed controlled by firmware proactive mechanisms |
Max. Airflow (each module) |
High speed: 90CFM Low speed: 70.7CFM |
Environmental Specifications
Humidity |
Operating: 5% to 95% (non-condensing) Non-operating: 5% to 95% (non-condensing) |
---|---|
Temperature |
Operating: 0° to 40°C (32°F to 104°F) Non-operating: -40° to 60°C (-40°F to 149°F) |
Altitude |
Operating: Sea level to 3,658m (12,000 ft.) Non-operating: Sea level to 12,192m (40,000 ft.) |
Dimensions
Dimensions | With Forearm Handles (Not including rear-end protrusions) | Without Forearm Handles |
---|---|---|
Height | 131mm (5.2 inches) | 130mm (5.1 inches) |
Width | 482.6mm (19 inches) | 445mm (17.5 inches) |
Length | 504.3mm (19.8 inches) | 488.2mm (19.2 inches) |
System weight
Net Weight | S16S-J1000-S 27kg (59.52 pounds)/ S16S-J1000-R 28kg ( 61.73 pounds ) |
---|---|
Gross Weight | S16S-J1000-S 29.5kg (65.04 pounds)/ S16S-J1000-R 30.5kg( 67.24 pounds) |
Spare Parts
IFT-83S10J162 | SAS expander controller module, 2 x SAS 4x wide ports | |
---|---|---|
IFT-9270CHandR | Right-side chassis ear for EonStor 3U series, LED version subsystems | |
IFT-9273CHandLLCD | Left-side chassis ear for EonStor 3U series, LED version subsystems, with an LED panel | |
IFT-9273ECPSU | Power supply module for ES 3U, ASIC400 series subsystem, 530W capacity | |
IFT-9273ECFanMod | Cooling fan module for ES 3U, ASIC400 series subsystems | |
IFT-9373CDTray (S16S-J1000-S) | 3.5" Hard disk drive tray | |
IFT-9270CmSASCab3 | SAS external cable, MiniSAS 4X(SFF-8088) to Infiniband 4X(SFF-8470, thumbscrew type), 50 Centimeters |
Accessories
IFT-9270CSASCab02 | SAS external cable, SFF-8470 connectors, 120cm | |
---|---|---|
IFT-9272CDTrayDmy | Dummy Drive tray, Type-II bezel | |
IFT-9273CSlider32 | Slide rail assembly, for Enhanced ES 3U/16-bay subsystem, 23"~32" rack depth | |
IFT-9273CSlider36 | Slide rail assembly, for Enhanced ES 3U/16-bay subsystem, 23"~36" rack depth |